In accordance with section 39.2 of the Consumer Protection Act (CQLR, c. P-40.1), Dimex360 Inc. guarantees the availability of replacement parts as well as the information necessary for the maintenance of the products it sells. Dimex360 Inc. may replace a product when applicable, but does not offer any repair services. Dimex360 Inc. cannot act as a certified plumber and therefore cannot offer installation, repair, or plumbing services.
Popular Categories
New Products
Troubleshooting
Helping you resolve problems quickly and efficiently.
Verify that the aerator isn’t clogged. Remove it, clean it with water, and reinstall.
- Check if the shut-off valves under the sink are fully open.
- Inspect the supply lines for kinks or blockages.
Generally due to a worn or dirty cartridge.
- Remove and clean the cartridge according to the instructions in your manual.
- If the problem persists, the cartridge may need to be replaced.
- Check the anti-limescale nozzles. Gently rub the nozzles with your fingers to remove limescale buildup.
- If necessary, soak the showerhead or hand shower in a solution of equal parts warm water and white vinegar for several hours, then rinse thoroughly.
- Disassemble and inspect the product.
- Clean any mineral buildup from the nozzles and check for possible obstructions.
For a pressure-balanced valve:
- Frequent temperature variations are usually caused by sudden changes in water pressure within the plumbing system (e.g., simultaneous use of other faucets or appliances).
- Check and clean the pressure balance cartridge according to your manual.
- Ensure the cartridge is free from mineral deposits by cleaning it with a vinegar-water solution.
- Apply plumbing grease before reinstalling to optimize functionality.
For a thermostatic valve:
- Constant fluctuations usually indicate that the thermostatic cartridge is obstructed or that mineral deposits prevent precise temperature regulation.
- Remove the thermostatic cartridge as per your manual, then thoroughly clean it with a vinegar-water solution.
- Check the condition of the integrated filter (if applicable), clean it or replace it if necessary.
- Apply plumbing grease before reinstalling to ensure precise temperature control.
- Ensure the pipes used meet recommendations (copper pipes recommended; PEX pipes may cause vibrations).
- Ensure all fittings are properly tightened and correctly installed.